Main Parameters » History » Version 9

« Previous - Version 9/68 (diff) - Next » - Current version
HAENNIG, Gerald, 12/13/2015 10:36 PM


2.3 Main Parameters

This part lists the main specifications and highlights the main parameters to compare an optical link with a coaxial cable

2.3.1 Optical link

The optical link consists of :
  • Optical transmitter OTX1910 : it modulates the intensity of the optical 1320 nm wavelength with the RF input signal ;
  • Monomode fiber 9/125 OS2 (to avoid dispersion effect) to optical signal on a distance up to 10 kilometers ;
  • Optical Receiver ORX1900 : it detects optical wavelength intensity modulation and outputs the RF modulating signal.
Parameter Unit Measurements
Frequency MHz 700 1000 1500 2000 2300
Optical Link Noise Figure dB 30.9 30.1 31.3 32.6 33.4
Optical transmitter OTX1910 min typ max Unit comments
Supply 9 12 14 V
Current consumption - - 450 mA
RF Input Connector 75 Ohm F-type

RF Return Loss 14 - - dB
RF Maximum Input Level - - 15 dBm
RF Input Dynamic Range -65 - -10 dBm
RF Input Frequency 700 - 2300 MHz
Optical Connecctor LC/PC single mode
Optical signal wavelength - 1310 - nm
Optical power level - 1 - dBm

2.3.2 Coaxial cable