22 Measurements regarding the useful signal and approximation of the signal-to-noise ratio » History » Version 3

« Previous - Version 3/9 (diff) - Next » - Current version
JANVIER, Thibault, 12/15/2015 01:14 AM


2.2. Measurements regarding the useful signal and approximation of the signal-to-noise ratio

To carry out measurements on the desired channel, the USRP has to be reconfigured. To do so, the program needs to stop running. Then, the selection of the tabs “USRP Configuration” and “Power Spectrum Signal” in the “Analog” thumb index will allow configuring the USRP and displaying the results.
The USRP down-converts the incoming signal according to the local oscillator frequency that is indicated as an input by the control command “carrier frequency”. Then it samples the down-converted signal at a sample rate given by the control command “IQ sampling rate”. To display the power spectrum of the entire channel, a down-conversion with a local oscillator frequency of 1,6 GHz has been chosen. Then the sampling rate has been set to 40 MHz to have a span of 20 MHz on the displayed power spectrum (from 1,6 GHz to 1,62 GHz). While the program is running, it is possible to configure in real time the settings of the power spectrum of the signal. The value “-1” that is set for the resolution bandwidth is a default value that chooses automatically the best resolution bandwidth possible taking into account the other parameters. The results are shown below.